Seitenansicht 225
Tool Calibration with TT 110
Function MP
No. Bit
A B C Input AE-6
Entry value
Tool calibration cycles 6500 -

0 = cycles inhibited
1 = cycles not inhibited
0
Probing direction for tool
calibration
6505 -

0 = pos. probing direction in the angle
reference axis (0° axis)
1 = pos. probing direction in the +90° axis
2 = neg. probing direction in the angle
reference axis (0° axis)
3 = neg. probing direction in the +90° axis
0
Calculating the probing feed rate 6507 -

0 = calculation of probing feed rate with constant
tolerance
1 = calculation of probing feed rate with variable
tolerance
2 = constant probing feed
0
Maximum permissible measuring
error
for measurement with a rotating tool
6510 -

0.002 to 0.999 [mm] 0.005
Probing feed rate
for measurement with a non-rotating tool
6520 -

10 to 3 000 [mm/min] 10
Distance between lower edge of
tool and upper edge of stylus
for tool radius measurement
6530 -

0.001 to 99.9999 [mm] 10
Diameter or edge length of the
TT 110 stylus
6531 -

0.001 to 99 999.9999 [mm] 10
R H
1.0 TNC
415B/425/426
Machine Parameters MP 6500 - MP 6531 03.01.95 5.2 48